Model No: 16993

Serial No: 1393-092R0028N0006

Product ID: 800-6124

Ideal for micro to large-scale cell culture applications, the Vi-CELL MetaFLEX bioanalyte analyzer delivers fast, accurate analysis of pH, pO2, pCO2, glucose, lactate, electrolytes and more parameters. The system provides an automatic quality management system with 3 dedicated on-board QC solutions and customizable QC schedule. Security and data log features help you comply with 21 CFR Part 11 guidelines.

Specifications:

  • Platform:Vi-Cell
  • Temperature Range:Operating temperature range: 15°C to 32°C
  • Power Requirements:100-240 VAC
  • Weight:11 kg(24.2 lb)
  • Width:25 cm(9.8 in)
  • Depth:29 cm (base instrument without integration deck)
  • Height:45 cm(17.7 in)
  • Acoustic noise:
  • In front of the analyzer, when no activities are done:>27 dB.
  • During automatic activities:>36 dB.
  • During measurements and when data is printed:>55 dB.
  • Volume of sample necessary for aspiration
  • For the capillary 45 μL mode:45 μL.
  • For the syringe mode:65 μL.
  • Measuring time:
  • For the capillary 45 μL mode:≤60 seconds from the time the sample isaspirated until the results are shown.
  • For the syringe mode:35 seconds from the time the sample is aspirated until the results are shown.
  • Measurement cycle time:
  • For the capillary 45 μL mode: 85 seconds from the time the sample is aspirated until the analyzer is ready to analyze the next sample.
  • For the capillary 45 μL and syringe 65 μL modes: 60 seconds from the time the sample is aspirated until the analyzer is ready to analyze the next sample.
  • The time may be different during Start up.
  • Number of samples per hour: 
  • For the capillary 45 μL mode ≤35 samples per hour.
  • For the syringe 65 μL modes: ≤44 samples per hour.
  • During Start up: For the capillary 45 μL mode: ≤13 samples per hour.
  • During Start up: For the capillary 45 μL and syringe 65 μL modes: ≤15 samples per hour.
  • External serial port:
  • 1 × RS-232 (9-pin) connector. Baud rate: 1200, 2400, 4800, 9600, 14400,

19200, 38400.

  • USB ports:
  1.  3 (1 at the top and 2 in the back of the analyzer).
  2. NOTE Only the USB port at the top of the analyzer can be used for the WIFI Adapter.
  • Ethernet:1 × RJ45 connector, 100Base-Tx Fast Ethernet
  • Keyboard/mouse port:PS/2
  • External VGA screen port:Connector for VGA screen (disabled in BIOS setting)